The KSL series designed and produced by Shanghai Jinshi Suotai Electromechanical Equipment Co., Ltd. and the air-water cooler for LAB backpack type DC motor are forced cooling devices for various types of DC motors.
This series of products integrates circulating fans, air filters and various testing devices. It is more convenient to install and maintain than the motors with centralized ventilation. It enables the motor to be protected to IP44 or IP54. The cooler adopts a bimetal rolled finned tube as a heat exchange component, and has the characteristics of large heat dissipation area, high heat transfer efficiency and long service life.
Our company can provide users with design and manufacture of various products under various working conditions.
KSLSeries air-water cooler main technical data
Seat number |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
|
Heat exchange power(kW) |
7 |
10 |
14 |
17 |
22 |
27 |
34 |
50 |
|
Cooling air volume(m3/s) |
1.1 |
1.1 |
1.2 |
1.3 |
1.6 |
1.6 |
1.9 |
2.4 |
|
Influent volume(L/s) |
0.9 |
1.2 |
1.8 |
2.2 |
3.0 |
3.0 |
4.0 |
4.0 |
|
Inlet temperature(℃) |
33 |
||||||||
Fan model |
Model |
T4-72 |
T4-72 |
4-79 |
4-79 |
4-79 |
4-79 |
4-79 |
T4-72 |
Power(kW) |
2.2 |
2.2 |
3 |
4 |
5.5 |
5.5 |
5.5 |
7.5 |
|
Rotating speed(rpm) |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
|
Wind pressure(Pa) |
1200 |
1200 |
1300 |
1500 |
1800 |
1800 |
1800 |
2000 |
|
Seat number |
400 |
450 |
810 |
812 |
814 |
816 |
818 |
|
|
Heat exchange power(kW) |
65 |
75 |
13 |
15 |
18 |
22 |
30 |
|
|
Cooling air volume(m³/s) |
3.2 |
3.2 |
1.3 |
1.3 |
1.3 |
1.3 |
1.3 |
|
|
Influent volume(L/s) |
4.5 |
4.8 |
2.2 |
2.2 |
2.5 |
2.7 |
2.7 |
|
|
Inlet temperature(℃) |
33 |
||||||||
Fan model |
Model |
T4-72 |
T4-72 |
4-79 |
4-79 |
4-79 |
4-79 |
4-79 |
|
Power(kW) |
11 |
11 |
4 |
4 |
4 |
4 |
4 |
|
|
Rotating speed(rpm) |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
|
|
Wind pressure(Pa) |
2400 |
2400 |
1500 |
1500 |
1500 |
1500 |
1500 |
|
LAWeries air-water cooler main technical data
Seat number |
315 |
355 |
400 |
450 |
500 |
560 |
710 |
900 |
|
Heat exchange power(kW) |
21 |
35 |
46 |
56 |
62 |
78 |
120 |
200 |
|
Cooling air volume(m³/s) |
1.1 |
1.67 |
2.34 |
2.65 |
3 |
4.3 |
6.4 |
11 |
|
Influent volume(L/s) |
1.3 |
2.2 |
3.3 |
4.0 |
4.3 |
4.7 |
6.5 |
11.2 |
|
Inlet temperature(℃) |
32 |
||||||||
Fan model |
T4-72-12 |
3.5 |
4 |
4.5 |
4.5 |
4.5 |
5 |
8 |
2X5 |
Power(kW) |
2.2 |
5.5 |
7.5 |
7.5 |
7.5 |
15 |
18.5 |
2X15 |
|
Rotating speed(rpm) |
2900 |
2900 |
2900 |
2900 |
2900 |
2900 |
1450 |
2900 |
|
Wind pressure(Pa) |
1300 |
1700 |
2200 |
2200 |
2200 |
2700 |
2500 |
2700 |
The company adheres to the corporate policy of innovation, development and quality, continuously researches, designs and develops, enhances the technical content of products, and spares no effort to provide users with quality products and provide thoughtful services.